HEATING, VENTILATION AND AIR CONDITIONING (HVAC) CONTROL SYSTEMS

SELECTED PRODUCTS BY CATEGORY:

Main modules

LPC-2.MM1 | PLC main control module, Web server, Wifi, Daisy chain Ethernet with Gigabit port

  • Real Time Linux OS ARM based main module
  • 2x Ethernet port (10/100T) with Modbus TCP/IP Slave (server) and/or Master (client) with daisy chain functionality
  • 1x Ethernet port (10/100/1000T) with Modbus TCP/IP Slave (server) and/or Master (client) functionality
  • USB port for Debugging and application transfer, USB OTG
  • BACnet IP (B-ASC), web server and SSL
  • Wifi connectivity
  • Modbus RTU Master or Slave
  • Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
  • RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
  • RAM: 1 GB DDR3
  • Flash: 4GB
  • CPU: iMX6 1GHz
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.MM2 | PLC main control module, Web server, Wifi, Daisy chain Ethernet

  • Real Time Linux OS ARM based main module
  • 2x Ethernet port (10/100T) with Modbus TCP/IP Slave (server) and/or Master (client) with daisy chain functionality
  • USB port for Debugging and application transfer, USB OTG
  • BACnet IP (B-ASC), web server and SSL
  • Wifi connectivity
  • Modbus RTU Master or Slave
  • Modbus RTU port Master or Slave
  • Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
  • RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
  • RAM: 1 GB DDR3
  • Flash: 4GB
  • CPU: iMX6 1GHz
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.MC9 | PLC main control module

  • Real Time Linux OS ARM based main module
  • Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality
  • USB port for Debugging and application transfer
  • Two CAN ports – one for master, one for slave
  • Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
  • RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
  • BACnet IP (B-ASC), web server and SSL
  • Mains power supplied
  • Modbus RTU Master or Slave
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.MC8 | PLC main control module

  • 4 kb Flash memory available for parameter storage
  • Ethernet connectivity with Modbus TCP slave (server) functionality
  • USB port for Debugging, Application and Default parameters transfer
  • Two CAN ports – one for master, one for slave
  • Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
  • Integrated RTC with Super Cap backup
  • 32 kB non-volatile memory
  • Mains power supplied
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Communication modules

LPC-2.EO1 | EnOcean wireless module

  • EnOcean transceiver module based on EnOcean TCM320 module with integrated whip antenna
  • Up to 5 receiver and 5 transmitter EnOcean devices supported
  • 868 MHz or 315 MHz EnOcean radio standard1
  • Typical working range inside buildings is up to 30m
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.C05 | GSM module

  • Dual band 900/1800 MHz
  • Optional RS-232 communication port, 9600 bps, 8 bits, one stop bit, no parity, no flow control, reserved for external AT command
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Digital input modules

LPC-2.DI1 | 1DI digital input module volt-free

  • 1 standard digital input, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI5 | 8DI digital input module volt-free

  • 8 standard digital inputs, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.I16 | 16DI digital input module volt-free or 24 V DC

  • 16 voltage free or standard digital inputs, galvanic isolated
  • Flexible inputs for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI3 | 1DI digital input module 24 V DC

  • 1 standard digital input, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI6 | 8DI digital input module 24 V DC

  • 8 external 24 V DC digital inputs, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI4 | 1DI digital input module 24 V AC

  • 1 standard digital input, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI7 | 8DI digital inputs module 24 V AC

  • 8 external 24 V AC digital inputs, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI2 | 1DI Digital input module 230 V AC

  • 1 direct 230 V AC digital input, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DI8 | 8DI digital input module 230 V AC

  • 8 direct 230 V AC digital inputs, galvanic isolated
  • Flexible input for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Digital output modules

LPC-2.DO2 | 1DO (NO) relay output module

  • 1 relay digital output with make contacts (NO), galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO3 | 1DO (NC) relay output module

  • 1 relay digital output with brake contacts (NC), galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO6 | 8DO (NO) relay output module

  • 8 relay digital outputs with make contacts (NO), galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO8 | 8DO (NC) relay output module

  • 8 relay digital outputs with break contacts (NC), galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO1 | 1DO 24 V DC transistor output module

  • 1 standard transistor digital output, current limited, galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.O16 | 16DO 24 V DC transistor output module

  • 16 standard transistor digital outputs, current limited, galvanic isolated
  • Flexible output for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO4 | 1DO 24 .. 230 V AC triac output module

  • 1 snubberless zero crossing triac output, galvanic isolated
  • Long life AC digital output
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO9 | 4DO 24 .. 230 V AC triac output module

  • 4 snubberless zero crossing triac outputs, galvanic isolated
  • Long life AC digital output
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DO7 | 8DO 24 .. 230 V AC triac output module

  • 8 snubberless zero crossing triac outputs, galvanic isolated
  • Long life AC digital output
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Analog modules

LPC-2.A05 | 8AIO 8AI analog input output module

  • 8 analog inputs: voltage input, current input, thermistor
  • analog inputs/outputs: voltage output, current output, thermistor, PWM output
  • Jumper selectable type of input/output
  • Signal LED
  • Small dimensions and standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.A02 | 2AI analog input module

  • 2 sensor inputs: thermocouples, NTC, Pt100, Pt1000 and Ni1000
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.A01 | 6AI 2AO analog input output module

  • 2 analog outputs voltage / current
  • 6 analog inputs voltage / current
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.A03 | 2AO analog output module

  • 2 analog outputs voltage / current
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.A04 | 8AO analog output module

  • 8 analog outputs voltage / current
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Dedicated modules

LPC-2.ED1 | Encoder stepper motor driver module

  • Bipolar stepper motor drive outputs (A, B, C, D) with 500 mA or 330 mA drive capability each
  • Internal +24 V DC or external 5 .. 36 V DC stepper motor power supply selection with jumper J6
  • Encoder inputs for incremental or count operation (A, A\; B, B\; Z, Z\)
  • Internal +5 V DC or +12 V DC encoder power supply selection with jumper J1
  • Encoder inputs type (RS-485 or TTL with pull up to +5 V DC) selection with jumpers J3 (A,A\), J4 (B,B\) and J5 (Z,Z\)
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.VV4 | Differential pressure I/O module

  • Differential pressure measurement up to 500 Pa
  • 3 x Voltage analog inputs: 0 .. 10 V
    1 x Voltage analog output: 0 .. 10 V
  • 1 x NTC 10k input
    1 x NTC 10k / voltage analog input: 0 .. 10 V, jumper selectable
  • 8 x Digital inputs
  • 2 x Relay outputs, NO
    2 x Relay outputs, NO / NC, jumper selectable
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.VV1 | Pressure sensor module

  • Differential pressure measurement up to 1000 Pa
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.DD4 | 4 channel MOSFET dimmer module

  • 4 channel MOSFET dimmer drive for dimmable lights or AC motor fans.
  • Operational power supply 90 .. 264 V AC, 50/60 Hz or 11.5 .. 30 V DC.
  • Overload protected
  • SW adjustable trailing-edge or leading-edge dimmer type, separately for each one of 4 channels.
  • SW adjustable fade-in and fade-out time effect, separately for each one of 4 channels.
  • Phase dependent driver for output which makes this module a lot more resistant to electrical disturbances than commonly used amplitude dependent drivers.
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.R01 | 7DO 6DI room module

  • 7 triac outputs
  • Electrical door lock output
  • 6 voltage free digital inputs
  • Galvanic isolated
  • Flexible inputs for wide use of operation
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

LPC-2.R02 | 4DO 3DI 4AO 2AI room module

  • 4 analog outputs, where Q2 and Q4 may also be used for GND connection (jumper selectable)
  • 2 analog inputs, where I2 input may also be used for NTC or GND connection (jumper selectable)
  • Analog input voltage range: 0 .. 10 V @ ±1 % measurement error of full scale
  • Analog output voltage output range: 0 .. 10 V @ ±1 % accuracy of full scale value
  • Tacho input
  • 3 voltage free digital inputs, galvanic isolated
  • Flexible digital input for wide use of operation
  • 3 snubberless zero crossing triacs output also suitable for use with inductive loads up to 0.9 A
  • 1 snubberless zero crossing triac output also suitable for use with inductive loads up to 3.5 A, with load test function
  • 24 V AC/DC power supply output with overload protection
  • Standard DIN EN50022-35 rail mounting

USER MANUAL

Intelligent peripheral modules

LPC-2.P02V | LED room thermostat (T)

  • Room temperature measurement
  • 2 push buttons for temperature set point
  • LED intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Frost protection function
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.P01V | LED room thermostat (T, 3-speed fan)

  •  Room temperature measurement
  • 2 push buttons for temperature set point
  • 1 push button for manual fan speed, auto and controller off
  • LED intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.DP2B | LCD room thermostat (T)

  • Room temperature measurement
  • 2+2 push buttons for temperature set point
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Frost protection function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.DP2BH | LCD Room thermostat (T/RH)

  • Room temperature and relative humidity measurement
  • 2+2 push buttons for temperature set point
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Frost protection function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.DP1B | LCD room thermostat (T, 3-speed fan)

  • Room temperature measurement
  • 2 push buttons for temperature set point
  • 2 push buttons for manual fan speed, auto and controller off
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.DP1BH | LCD room thermostat (T/RH, 3-speed fan)

  • Room temperature and relative humidity measurement
  • 2 push buttons for temperature set point
  • 2 push buttons for manual fan speed, auto and controller off
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door and window function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LPC-2.DT3 | LCD Room thermostat (T, 3-speed fan), access control reader & key card holder RFID Mifare, 8 gang touch switch

  • Frameless glass screen with LCD
  • 8 capacitive touch buttons
  • 8 blue LED, one on each touch button
  • 8 rectangular symbols to show on/off status on the LCD
  • Integrated ISO/IEC 14443 A/MIFARE RFID UID reader
  • Possibility to use as card access or card holder – supplied with two different plastic covers for RFID slot
  • Integrated temperature and light sensor
  • LCD intensity control
  • Color LCD with possibility of background picture changing and status symbols size changing
  • Buzzer for touch beep signalization or other signalization which is controlled from PLC program
  • Available in black or white colour finish
  • Flush mount or screw mount

USER MANUAL

LPC-2.TH1LPC-2.TH1 | Temperature & humidity (T/RH) module

  • Room temperature measurement
  • Room relative humidity measurement
  • Flush mount

USER MANUAL

LPC-2.AQ1 | Air quality module (VOC)

  • Air quality sensing module
  • DIP switch configurable RS-485 address
  • Status LEDs for IR and RS-485 communication
  • Flush mount

USER MANUAL

LPC-2.IR2V | IR multisensor (T/RH, IR, lux)

  • Room temperature and relative humidity measurement
  • Lux sensor for light intensity measurement
  • IR receive/transmit
  • Programmable IR transceiver
  • RC-5 IR protocol receiver
  • Daikin, Toshiba, Hitachi, Panasonic, Mitsubishi, LG IR protocol transmitter
  • Flush mount

USER MANUAL

LPC-2.RC1S | IR remote control

  • IR command transmitter
  • Robust design
  • Designed for building automation

USER MANUAL

LPC-2.SM5 | Multisensor (IR, lux, PIR, CO2)

  • CO2 sensor for CO2 measurement
  • PIR sensor for occupancy detection
  • Lux sensor for light intensity measurement
  • IR receive/transmit
  • Mounting with integrated magnets or screws

USER MANUAL

LPC-2.SM6 | Multisensor (IR, lux, PIR, VOC)

  • VOC sensor for VOC measurement
  • PIR sensor for occupancy detection
  • Lux sensor for light intensity measurement
  • IR receive/transmit
  • Mounting with integrated magnets or screws

USER MANUAL

LPC-2.SM7 | Multisensor (IR, lux, T)

  • IR matrix sensor for temperature measurement
  • Lux sensor for light intensity measurement
  • IR receive/transmit
  • Mounting with integrated magnets or screws

USER MANUAL

Modbus RTU temperature control panels

LMP-1.MP2B | LCD Modbus RTU room thermostat (T)

  • Room temperature measurement
  • 2+2 push buttons for temperature set point
  • 10 position LCD bar-graph for temperature set point
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door/window function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LMP-1.MP2BH | LCD Modbus RTU room thermostat (T/RH)

  • Room temperature and humidity measurement
  • 2 + 2 Push buttons for temperature set point
  • 10 position LCD bar-graph for temperature set point
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door/window function
  • Color LCD display with background picture customization possibility
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LMP-1.MP1B | LCD Modbus RTU room thermostat (T, 3-speed fan)

  • Room temperature measurement
  • 2 push buttons for temperature set point
  • 2 push buttons for manual fan speed, auto and controller off
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door/window function
  • Color LCD display with background picture customization possibility
  • Step-less or 3 step fan motor controlling
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

LMP-1.MP1BH | LCD Modbus RTU room thermostat (T/RH, 3-speed fan)

  • Room temperature and humidity measurement
  • 2 push buttons for temperature set point
  • 2 push buttons for manual fan speed, auto and controller off
  • LCD intensity control
  • Economic function
  • 2/4 pipe heating cooling system supported
  • Balcony door/window function
  • Color LCD display with background picture customization possibility
  • Step-less or 3 step fan motor controlling
  • Available in black or white colour finish
  • Flush mount

USER MANUAL

4.3” LCD PLC based touch screens

LPC-3.GOT.111 | 4.3`` LCD PLC HMI touch screen, capacitive, temperature

  • Frameless glass screen with 4.3” LCD display and capacitive touch screen
    – landscape or portrait orientation
  • Graphical interface is freely designed by the user with GUI editor in SmartehIDE
  • Integrated temperature and light sensor
  • Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality,
    BACnet IP (B-ASC), web server and SSL
  • Modbus RTU Master or Slave
  • USB port for Debugging and application transfer
  • Remote access and application transfer
  • Two CAN ports – one for master, one for slave
  • RTC and 512 kB NV RAM with super capacitor for needed energy storage
  • Display brightness level controlled from PLC program
  • Available in black or white colour finish
  • Flush mount or screw mount

USER MANUAL

LPC-3.GOT.131 | 4.3`` LCD PLC HMI touch screen, capacitive, temperature, RFID Mifare

  • Frameless glass screen with 4.3” LCD display with capacitive touch screen
    – landscape or portrait orientation
  • Graphical interface is freely designed by the user with GUI editor in SmartehIDE
  • Integrated ISO/IEC 14443 A/MIFARE RFID UID reader
  • Mifare Classic 1K, 2K, 4K NDEF reader and writer
  • Integrated temperature and light sensor
  • Possibility to use as card access or card holder – supplied with two different plastic covers for RFID slot
  • Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality,
    BACnet IP (B-ASC), web server and SSL
  • Modbus RTU Master or Slave
  • USB port for Debugging and application transfer
  • Remote access and application transfer
  • Two CAN ports – one for master, one for slave
  • RTC and 512 kB NV RAM with super capacitor for needed energy storage
  • Display brightness level controlled from PLC program
  • Available in black or white colour finish
  • Flush mount or screw mount

USER MANUAL

Connection of intelligent peripheral panels

Interconnection cable SSK

USER MANUAL

Interconnection cable ICM-7

USER MANUAL

Splitter SPL-1 (1/2)

USER MANUAL

Splitter SPL-2 (1/8)

USER MANUAL

Splitter SPL-5

USER MANUAL

Temperature sensors

NTC-1 | Temperature sensor 10k

  • Operating temperature -40 .. 80°C
  • Max. power at 25 °C 200mW
  • Rated temperature 25°C
  • Rated resistance 10kW ±5%
  • Standard cable length 0,7m, 2m, 7m, 10m,…

USER MANUAL

NTC-4 | Temperature sensor 10k

  • RIT lable EPCOS B57891
  • Operating temperature -40 .. 80°C
  • Max. power at 25 °C 200mW
  • Rated temperature 25°C
  • Rated resistance 10kW ±5%
  • Standard cable length 4m, 7m,…

USER MANUAL

NTC-5 | Temperature sensor 10k panel

  • Operating temperature -40 .. 80°C
  • Max. power at 25 °C 200mW
  • Rated temperature 25°C
  • Rated resistance 10kW ±5%
  • Available in black or white colour finish

USER MANUAL

Magnetic sensors

Wireless solar power switch

USER MANUAL

Condensation, water leakage, occupancy detectors

LCS-1.C01 | Condensation sensor

  • Wide power supply range 5 .. 32 V DC/AC
  • Output voltage free contact
  • Condensation two LEDs indication
  • Provided spring for pipe mounting

USER MANUAL

LCS-1.C02 | Condensation sensor

  • Wide voltage operating range 10 .. 32 V DC
  • Two flying lead wires connection
  • Condensation LED indication
  • Provided spring for on pipe mounting

USER MANUAL

LOC-1 | Occupancy sensor

  • Wide power supply range 5 .. 32 V DC/AC
  • Output voltage free contact
  • Mounting with integrated magnets or screws
  • Convenient enclosure for multi mounting possibilities
  • 2 diagnose LED

USER MANUAL

LOC-2 | Occupancy sensor

  • Wide voltage operating range 10 .. 32 V DC
  • Two flying lead wires connection
  • Mounting with integrated magnets or screws
  • Convenient enclosure for multi mounting possibilities
  • 1 diagnose LED

USER MANUAL

GSM commander GM2

GM2 | GSM commander

USER MANUAL

Silent motor drive LMD2

LMD-2.U01 | Silent motor drive

  • Variable voltage output
  • Load up to 250 VA
  • Various input control signals

USER MANUAL

Power supply modules

APS-1 | Adjustable power supply 5V2

USER MANUAL

APS-04 | Adjustable power supply 24V 60W

USER MANUAL

USB to serial RS-232 / RS-485 adapter

LSA-2.USB | USB RS-232/RS-485 adapter

  • Optically isolated RS-232 and RS-485 ports
  • Speeds up 115 kbps
  • Galvanic isolated power supply
  • Diagnose LEDs
  • Small compact enclosure

USER MANUAL