SELECTED PRODUCTS BY CATEGORY:
Main modules
LPC-2.MM1 | PLC main control module, Web server, Wifi, Daisy chain Ethernet with Gigabit port
- Real Time Linux OS ARM based main module
- 2x Ethernet port (10/100T) with Modbus TCP/IP Slave (server) and/or Master (client) with daisy chain functionality
- 1x Ethernet port (10/100/1000T) with Modbus TCP/IP Slave (server) and/or Master (client) functionality
- USB port for Debugging and application transfer, USB OTG
- BACnet IP (B-ASC), web server and SSL
- Wifi connectivity
- Modbus RTU Master or Slave
- Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
- RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
- RAM: 1 GB DDR3
- Flash: 4GB
- CPU: iMX6 1GHz
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.MM2 | PLC main control module, Web server, Wifi, Daisy chain Ethernet
- Real Time Linux OS ARM based main module
- 2x Ethernet port (10/100T) with Modbus TCP/IP Slave (server) and/or Master (client) with daisy chain functionality
- USB port for Debugging and application transfer, USB OTG
- BACnet IP (B-ASC), web server and SSL
- Wifi connectivity
- Modbus RTU Master or Slave
- Modbus RTU port Master or Slave
- Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
- RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
- RAM: 1 GB DDR3
- Flash: 4GB
- CPU: iMX6 1GHz
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.MC9 | PLC main control module
- Real Time Linux OS ARM based main module
- Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality
- USB port for Debugging and application transfer
- Two CAN ports – one for master, one for slave
- Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
- RTC and 512 kB non-volatile memory with super capacitor for needed energy storage
- BACnet IP (B-ASC), web server and SSL
- Mains power supplied
- Modbus RTU Master or Slave
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.MC8 | PLC main control module
- 4 kb Flash memory available for parameter storage
- Ethernet connectivity with Modbus TCP slave (server) functionality
- USB port for Debugging, Application and Default parameters transfer
- Two CAN ports – one for master, one for slave
- Smarteh bus for Smarteh intelligent peripheral modules (thermostat, RFID, IR, operator terminal,..)
- Integrated RTC with Super Cap backup
- 32 kB non-volatile memory
- Mains power supplied
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Communication modules
LPC-2.EO1 | EnOcean wireless module
- EnOcean transceiver module based on EnOcean TCM320 module with integrated whip antenna
- Up to 5 receiver and 5 transmitter EnOcean devices supported
- 868 MHz or 315 MHz EnOcean radio standard1
- Typical working range inside buildings is up to 30m
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.C05 | GSM module
- Dual band 900/1800 MHz
- Optional RS-232 communication port, 9600 bps, 8 bits, one stop bit, no parity, no flow control, reserved for external AT command
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Digital input modules
LPC-2.DI1 | 1DI digital input module volt-free
- 1 standard digital input, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI5 | 8DI digital input module volt-free
- 8 standard digital inputs, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.I16 | 16DI digital input module volt-free or 24 V DC
- 16 voltage free or standard digital inputs, galvanic isolated
- Flexible inputs for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI3 | 1DI digital input module 24 V DC
- 1 standard digital input, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI6 | 8DI digital input module 24 V DC
- 8 external 24 V DC digital inputs, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI4 | 1DI digital input module 24 V AC
- 1 standard digital input, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI7 | 8DI digital inputs module 24 V AC
- 8 external 24 V AC digital inputs, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI2 | 1DI Digital input module 230 V AC
- 1 direct 230 V AC digital input, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DI8 | 8DI digital input module 230 V AC
- 8 direct 230 V AC digital inputs, galvanic isolated
- Flexible input for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Digital output modules
LPC-2.DO2 | 1DO (NO) relay output module
- 1 relay digital output with make contacts (NO), galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO3 | 1DO (NC) relay output module
- 1 relay digital output with brake contacts (NC), galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO6 | 8DO (NO) relay output module
- 8 relay digital outputs with make contacts (NO), galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO8 | 8DO (NC) relay output module
- 8 relay digital outputs with break contacts (NC), galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO1 | 1DO 24 V DC transistor output module
- 1 standard transistor digital output, current limited, galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.O16 | 16DO 24 V DC transistor output module
- 16 standard transistor digital outputs, current limited, galvanic isolated
- Flexible output for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO4 | 1DO 24 .. 230 V AC triac output module
- 1 snubberless zero crossing triac output, galvanic isolated
- Long life AC digital output
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO9 | 4DO 24 .. 230 V AC triac output module
- 4 snubberless zero crossing triac outputs, galvanic isolated
- Long life AC digital output
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DO7 | 8DO 24 .. 230 V AC triac output module
- 8 snubberless zero crossing triac outputs, galvanic isolated
- Long life AC digital output
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Analog modules
LPC-2.A05 | 8AIO 8AI analog input output module
- 8 analog inputs: voltage input, current input, thermistor
- analog inputs/outputs: voltage output, current output, thermistor, PWM output
- Jumper selectable type of input/output
- Signal LED
- Small dimensions and standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.A02 | 2AI analog input module
- 2 sensor inputs: thermocouples, NTC, Pt100, Pt1000 and Ni1000
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.A01 | 6AI 2AO analog input output module
- 2 analog outputs voltage / current
- 6 analog inputs voltage / current
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.A03 | 2AO analog output module
- 2 analog outputs voltage / current
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.A04 | 8AO analog output module
- 8 analog outputs voltage / current
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Dedicated modules
LPC-2.ED1 | Encoder stepper motor driver module
- Bipolar stepper motor drive outputs (A, B, C, D) with 500 mA or 330 mA drive capability each
- Internal +24 V DC or external 5 .. 36 V DC stepper motor power supply selection with jumper J6
- Encoder inputs for incremental or count operation (A, A\; B, B\; Z, Z\)
- Internal +5 V DC or +12 V DC encoder power supply selection with jumper J1
- Encoder inputs type (RS-485 or TTL with pull up to +5 V DC) selection with jumpers J3 (A,A\), J4 (B,B\) and J5 (Z,Z\)
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.VV4 | Differential pressure I/O module
- Differential pressure measurement up to 500 Pa
- 3 x Voltage analog inputs: 0 .. 10 V
1 x Voltage analog output: 0 .. 10 V - 1 x NTC 10k input
1 x NTC 10k / voltage analog input: 0 .. 10 V, jumper selectable - 8 x Digital inputs
- 2 x Relay outputs, NO
2 x Relay outputs, NO / NC, jumper selectable - Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.VV1 | Pressure sensor module
- Differential pressure measurement up to 1000 Pa
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.DD4 | 4 channel MOSFET dimmer module
- 4 channel MOSFET dimmer drive for dimmable lights or AC motor fans.
- Operational power supply 90 .. 264 V AC, 50/60 Hz or 11.5 .. 30 V DC.
- Overload protected
- SW adjustable trailing-edge or leading-edge dimmer type, separately for each one of 4 channels.
- SW adjustable fade-in and fade-out time effect, separately for each one of 4 channels.
- Phase dependent driver for output which makes this module a lot more resistant to electrical disturbances than commonly used amplitude dependent drivers.
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.R01 | 7DO 6DI room module
- 7 triac outputs
- Electrical door lock output
- 6 voltage free digital inputs
- Galvanic isolated
- Flexible inputs for wide use of operation
- Standard DIN EN50022-35 rail mounting
USER MANUAL
LPC-2.R02 | 4DO 3DI 4AO 2AI room module
- 4 analog outputs, where Q2 and Q4 may also be used for GND connection (jumper selectable)
- 2 analog inputs, where I2 input may also be used for NTC or GND connection (jumper selectable)
- Analog input voltage range: 0 .. 10 V @ ±1 % measurement error of full scale
- Analog output voltage output range: 0 .. 10 V @ ±1 % accuracy of full scale value
- Tacho input
- 3 voltage free digital inputs, galvanic isolated
- Flexible digital input for wide use of operation
- 3 snubberless zero crossing triacs output also suitable for use with inductive loads up to 0.9 A
- 1 snubberless zero crossing triac output also suitable for use with inductive loads up to 3.5 A, with load test function
- 24 V AC/DC power supply output with overload protection
- Standard DIN EN50022-35 rail mounting
USER MANUAL
Intelligent peripheral modules
LPC-2.P02V | LED room thermostat (T)
- Room temperature measurement
- 2 push buttons for temperature set point
- LED intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Frost protection function
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.P01V | LED room thermostat (T, 3-speed fan)
- Room temperature measurement
- 2 push buttons for temperature set point
- 1 push button for manual fan speed, auto and controller off
- LED intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.DP2B | LCD room thermostat (T)
- Room temperature measurement
- 2+2 push buttons for temperature set point
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Frost protection function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.DP2BH | LCD Room thermostat (T/RH)
- Room temperature and relative humidity measurement
- 2+2 push buttons for temperature set point
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Frost protection function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.DP1B | LCD room thermostat (T, 3-speed fan)
- Room temperature measurement
- 2 push buttons for temperature set point
- 2 push buttons for manual fan speed, auto and controller off
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.DP1BH | LCD room thermostat (T/RH, 3-speed fan)
- Room temperature and relative humidity measurement
- 2 push buttons for temperature set point
- 2 push buttons for manual fan speed, auto and controller off
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door and window function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LPC-2.DT3 | LCD Room thermostat (T, 3-speed fan), access control reader & key card holder RFID Mifare, 8 gang touch switch
- Frameless glass screen with LCD
- 8 capacitive touch buttons
- 8 blue LED, one on each touch button
- 8 rectangular symbols to show on/off status on the LCD
- Integrated ISO/IEC 14443 A/MIFARE RFID UID reader
- Possibility to use as card access or card holder – supplied with two different plastic covers for RFID slot
- Integrated temperature and light sensor
- LCD intensity control
- Color LCD with possibility of background picture changing and status symbols size changing
- Buzzer for touch beep signalization or other signalization which is controlled from PLC program
- Available in black or white colour finish
- Flush mount or screw mount
USER MANUAL
LPC-2.TH1LPC-2.TH1 | Temperature & humidity (T/RH) module
- Room temperature measurement
- Room relative humidity measurement
- Flush mount
USER MANUAL
LPC-2.AQ1 | Air quality module (VOC)
- Air quality sensing module
- DIP switch configurable RS-485 address
- Status LEDs for IR and RS-485 communication
- Flush mount
USER MANUAL
LPC-2.IR2V | IR multisensor (T/RH, IR, lux)
- Room temperature and relative humidity measurement
- Lux sensor for light intensity measurement
- IR receive/transmit
- Programmable IR transceiver
- RC-5 IR protocol receiver
- Daikin, Toshiba, Hitachi, Panasonic, Mitsubishi, LG IR protocol transmitter
- Flush mount
USER MANUAL
LPC-2.RC1S | IR remote control
- IR command transmitter
- Robust design
- Designed for building automation
USER MANUAL
LPC-2.SM5 | Multisensor (IR, lux, PIR, CO2)
- CO2 sensor for CO2 measurement
- PIR sensor for occupancy detection
- Lux sensor for light intensity measurement
- IR receive/transmit
- Mounting with integrated magnets or screws
USER MANUAL
LPC-2.SM6 | Multisensor (IR, lux, PIR, VOC)
- VOC sensor for VOC measurement
- PIR sensor for occupancy detection
- Lux sensor for light intensity measurement
- IR receive/transmit
- Mounting with integrated magnets or screws
USER MANUAL
LPC-2.SM7 | Multisensor (IR, lux, T)
- IR matrix sensor for temperature measurement
- Lux sensor for light intensity measurement
- IR receive/transmit
- Mounting with integrated magnets or screws
USER MANUAL
Modbus RTU temperature control panels
LMP-1.MP2B | LCD Modbus RTU room thermostat (T)
- Room temperature measurement
- 2+2 push buttons for temperature set point
- 10 position LCD bar-graph for temperature set point
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door/window function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LMP-1.MP2BH | LCD Modbus RTU room thermostat (T/RH)
- Room temperature and humidity measurement
- 2 + 2 Push buttons for temperature set point
- 10 position LCD bar-graph for temperature set point
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door/window function
- Color LCD display with background picture customization possibility
- Available in black or white colour finish
- Flush mount
USER MANUAL
LMP-1.MP1B | LCD Modbus RTU room thermostat (T, 3-speed fan)
- Room temperature measurement
- 2 push buttons for temperature set point
- 2 push buttons for manual fan speed, auto and controller off
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door/window function
- Color LCD display with background picture customization possibility
- Step-less or 3 step fan motor controlling
- Available in black or white colour finish
- Flush mount
USER MANUAL
LMP-1.MP1BH | LCD Modbus RTU room thermostat (T/RH, 3-speed fan)
- Room temperature and humidity measurement
- 2 push buttons for temperature set point
- 2 push buttons for manual fan speed, auto and controller off
- LCD intensity control
- Economic function
- 2/4 pipe heating cooling system supported
- Balcony door/window function
- Color LCD display with background picture customization possibility
- Step-less or 3 step fan motor controlling
- Available in black or white colour finish
- Flush mount
USER MANUAL
4.3” LCD PLC based touch screens
LPC-3.GOT.111 | 4.3`` LCD PLC HMI touch screen, capacitive, temperature
- Frameless glass screen with 4.3” LCD display and capacitive touch screen
– landscape or portrait orientation - Graphical interface is freely designed by the user with GUI editor in SmartehIDE
- Integrated temperature and light sensor
- Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality,
BACnet IP (B-ASC), web server and SSL - Modbus RTU Master or Slave
- USB port for Debugging and application transfer
- Remote access and application transfer
- Two CAN ports – one for master, one for slave
- RTC and 512 kB NV RAM with super capacitor for needed energy storage
- Display brightness level controlled from PLC program
- Available in black or white colour finish
- Flush mount or screw mount
USER MANUAL
LPC-3.GOT.131 | 4.3`` LCD PLC HMI touch screen, capacitive, temperature, RFID Mifare
- Frameless glass screen with 4.3” LCD display with capacitive touch screen
– landscape or portrait orientation - Graphical interface is freely designed by the user with GUI editor in SmartehIDE
- Integrated ISO/IEC 14443 A/MIFARE RFID UID reader
- Mifare Classic 1K, 2K, 4K NDEF reader and writer
- Integrated temperature and light sensor
- Possibility to use as card access or card holder – supplied with two different plastic covers for RFID slot
- Ethernet connectivity with Modbus TCP/IP Slave (server) and/or Master (client) functionality,
BACnet IP (B-ASC), web server and SSL - Modbus RTU Master or Slave
- USB port for Debugging and application transfer
- Remote access and application transfer
- Two CAN ports – one for master, one for slave
- RTC and 512 kB NV RAM with super capacitor for needed energy storage
- Display brightness level controlled from PLC program
- Available in black or white colour finish
- Flush mount or screw mount
USER MANUAL
Temperature sensors
NTC-1 | Temperature sensor 10k
- Operating temperature -40 .. 80°C
- Max. power at 25 °C 200mW
- Rated temperature 25°C
- Rated resistance 10kW ±5%
- Standard cable length 0,7m, 2m, 7m, 10m,…
USER MANUAL
NTC-4 | Temperature sensor 10k
- RIT lable EPCOS B57891
- Operating temperature -40 .. 80°C
- Max. power at 25 °C 200mW
- Rated temperature 25°C
- Rated resistance 10kW ±5%
- Standard cable length 4m, 7m,…
USER MANUAL
NTC-5 | Temperature sensor 10k panel
- Operating temperature -40 .. 80°C
- Max. power at 25 °C 200mW
- Rated temperature 25°C
- Rated resistance 10kW ±5%
- Available in black or white colour finish
USER MANUAL
Magnetic sensors
Condensation, water leakage, occupancy detectors
LCS-1.C01 | Condensation sensor
- Wide power supply range 5 .. 32 V DC/AC
- Output voltage free contact
- Condensation two LEDs indication
- Provided spring for pipe mounting
USER MANUAL
LCS-1.C02 | Condensation sensor
- Wide voltage operating range 10 .. 32 V DC
- Two flying lead wires connection
- Condensation LED indication
- Provided spring for on pipe mounting
USER MANUAL
LOC-1 | Occupancy sensor
- Wide power supply range 5 .. 32 V DC/AC
- Output voltage free contact
- Mounting with integrated magnets or screws
- Convenient enclosure for multi mounting possibilities
- 2 diagnose LED
USER MANUAL
LOC-2 | Occupancy sensor
- Wide voltage operating range 10 .. 32 V DC
- Two flying lead wires connection
- Mounting with integrated magnets or screws
- Convenient enclosure for multi mounting possibilities
- 1 diagnose LED
USER MANUAL
GSM commander GM2
Silent motor drive LMD2
LMD-2.U01 | Silent motor drive
- Variable voltage output
- Load up to 250 VA
- Various input control signals
USER MANUAL
Power supply modules
USB to serial RS-232 / RS-485 adapter
LSA-2.USB | USB RS-232/RS-485 adapter
- Optically isolated RS-232 and RS-485 ports
- Speeds up 115 kbps
- Galvanic isolated power supply
- Diagnose LEDs
- Small compact enclosure
USER MANUAL